A square inch of downspout can drain 1 200 square feet of roof during a rain with an intensity of one inch per hour.
Gutter length per downspout.
Adding additional downspouts will require less gutter and downspout volume resulting in smaller gutters downspouts.
Offset of more than 10 ft 3 0 m can affect drainage capacity.
Gutter downspout sizes are 3 to 6 inches.
Doubling the number of downspouts halves the required capacity for each.
The downspout size must suit the bottom width of the gutter.
The gutter and downspout size required is highly dependent on the amount of gutter and the spacing of the downspouts.
For most homes this means installing spouts at either end of a gutter section.
As with gutters a downspout s capacity must match or exceed the expected runoff.
The gutter outlet capacity should suit the downspout capacity.
15 m is a practical maximum gutter length to be served by a downspout.
There is no linear foot of gutter per downspout calculation that can be made since it is the size of the area draining into that downspout that will tell you how much volume of water will typically drain through it.
As with gutters a downspout s capacity must match or exceed the expected runoff.
The standard is about inch per 10 feet.
The larger a gutter downspout the more water it can drain quickly.
You can t do the math like that.
However too large a gutter downspout can look unattractive.
Please lower the maximum spacing between downspouts to see this effect.
Size downspouts to fit the gutter.
To limit the effects of thermal expansion in gutters 50 ft.
The capacity of a sloped rectangular gutter may be approximated by using a gutter cross section area not less than that of a semicircular gutter and a depth to width ratio of at least 0 75.
Most downspouts are rectangular but they can also be round or square.
If we have to sum it up in a single rule gutters need a downspout around every 30 to 40 feet.
You should have enough gutter downspouts to effectively handle the size of your entire gutter system.
The above recommendations assume that you have properly sized downspouts every 40 feet.
Increasing the pitch increases a gutter s handling capacity but the gutter may look askew over a long run.
The standard is about inch per 10 feet.
Roof area the locale s rainfall intensity and gutter capacity determine how many square inches of downspout are needed.
Design of roof drainage systems.
The above recommendations assume that you have properly sized downspouts every 40 feet.
Increasing the pitch increases a gutter s handling capacity but the gutter may look askew over a long run.